USING THE FILL WEDGE COMMAND


     The Fill Wedge ( WG ) command, defines and fills a
     wedge using the current pen, the current line and fill
     types. The WG command includes an automatic pen down,
     and when the operation is complete, the original pen
     location and up/down status are restored. The syntax
     for the WG command is as follows:

     WG radius,start angle,sweep angle,[chord angle];

     For more information see the Updated PCL 5 Printer
     Language Technical Reference Manual.

     LEGEND: Ec = [Ctrl] [P] [Esc] in DOS EDIT.


     EcE                           Resets the printer.

     Ec%0B                         Enters HP-GL/2 mode.

     IN;                           Initializes HP-GL/2 mode.

     SP1;                          Selects pen number 1,
                                   (black). Even though
                                   there is no physical pen,
                                   the SP command must be
                                   used to enable printing.

     SC-3000,3000,-2000,2000,1;    Sets up user scaling,
                                   with P1 located at (-
                                   3000,-2000), and P2 being
                                   (3000,2000). The 1
                                   indicates isotropic
                                   scaling.

     PA0,0;FT3,75,45;WG-1000,90,180;    Enters absolute
                                   plotting mode and moves
                                   to user-unit position
                                   (0,0). Then selects fill
                                   type 3 (parallel lines),
                                   with 75 user-units
                                   between lines and the
                                   lines slanted 45 degrees.
                                   Then fills a wedge with
                                   the current fill pattern;
                                   using a radius of 1000
                                   user-units, a starting
                                   angle of 90 degrees and a
                                   sweep angle of 180
                                   degrees. The zero-degree
                                   reference point is on the
                                   left side of the circle
                                   (indicated by the
                                   negative radius parameter
                                   [-1000]).

     EW-1000,90,180;               Outlines (edges) the
                                   wedge just drawn with the
                                   commands above.

     FT4,60,45;WG-1000,330,120;    Selects fill type 4
                                   (cross-hatching),
                                   specifying 60 user-units
                                   between lines with the
                                   lines tilted at a 45
                                   degree angle. Fills a
                                   wedge that has the same
                                   radius and center point
                                   as the one above, but
                                   with a starting angle of
                                   330 degrees, and a sweep
                                   angle of 120 degrees.

     EW-1000,330,120;              Edges the wedge just
                                   drawn above.

     PR-60,110;FT1;                Specifies relative
                                   plotting and moves the
                                   pen 60 user-units to the
                                   left and 110 units up.
                                   Then selects fill type 1
                                   (solid black).

     WG-1000,270,60;               Fills a wedge, using the
                                   fill type just specified
                                   above, with a radius of
                                   1000 user-units, a start
                                   angle of 270 degrees, and
                                   a sweep angle of 60
                                   degrees.

     EW-1000,270,60;               Edges the wedge just
                                   drawn.

     Ec%0A                         Enters PCL mode.

     EcE                           Sends a reset to end the
                                   job and eject the page.



            Copyright  Hewlett-Packard Co. 1993
   The information contained herein is subject to change
                      without notice.
   Hewlett-Packard shall not be liable for incidental or
  consequential damages in connection with the use of this
                         material.